Universal Validation Reference Plate (VRP)

Validation Reference Plate is the direct response to feedback gained from training scientists, engineers and academic researchers developing assays with automated liquid handlers wanting automated volume verification & calibration by use of GLH QC Kit modified single dye method.

  • NIST Traceable, Chain of Custody
  • Validate Reader Performance
  • Validate Automated Pipetting Systems
  • No manual pipetting, eliminates operator error
  • Automatic standard curve for 96, 384, and 1536 microplates
More Info

Universal Validation Reference Plate (VRP)

Reword this:

Universal Validation Reference Plate (VRP) verifies microplate reader performance and auto-generates reference or standard curves to validate GLH QC Kit test results to achieve NIST Traceability.

GLH-Tracker Desktop software included with purchase of Universal Validation Reference Plate (VRP).

The VRP can be used in conjunction with the 96-Well and 384-Well GLH Verification Microplates to improve test performance.

Supports most plate readers

Insert VRP, scan in seconds, automatically generates standard curve for reader and assesses reader performance or volume verifies liquid handler.

For Absorbance 96 Mini-Reader

Universal Validation Reference Plate slim design works with USB powered Mini-Reader

What’s inside

Fixed pathlength known references

GLH QC Kit Workflow

Prep Plate

Dispense the reference plate and test plate with GLH QC Reagents and mix with plate shaker.

Read Plate

Simply scan the reference plate and the test plate, whether using our GLH QC Absorbance Mini Reader or your own plate reader.

Analyze and Report

GLHTracker software streamlines the entire workflow providing quality-compliant pass/fail results and detailed data for troubleshooting and optimization.

Detection method Absorbance
Detection mode Endpoint, kinetic
Microplates types 96-well microplates
Light source Up   to 6 LEDs
Detector 96   Photodiodes
Wavelength selection Example combinations (FWHM 10   nm): 450, 492, 562, 620 nm/405, 450, 540, 630 nm/492, 562, 605, 650 nm. Other   filter combinations in the range of 400–1000 nm possible.
Photometric range 0.0–4.0   OD
Linearity 405 nm: ≤ 1.5 % from 0.0–2.0 OD; ≤ 3.0   % from 2.0–3.0 OD

≥ 450 nm: ≤ 1.0 % from 0.0–2.0 OD; ≤   1.5 % from 2.0–3.0 OD

Accuracy 405 nm: ≤ 1.5 % + 0.010 OD from 0.0–2.0   OD; ≤ 3.0 % + 0.010 OD from 2.0–3.0 OD

≥ 450 nm: ≤ 1.0 % + 0.010 OD from   0.0–2.0 OD; ≤ 1.5 % + 0.010 OD from 2.0–3.0 OD

Reproducibility ≤ 0.5 % + 0.005 OD from 0.0–2.0 OD; ≤ 1 % + 0.010 OD from 2.0–3.0 OD
Resolution 0.001 OD
Read time Down   to 3 sec. at single wavelength
Data output USB   2.0 interface with PC.
Dimensions reader 9.6 x 15.4 x 5.5 cm (W x L x H)
Weight reader 900   g
Power supply USB   connection 5 V
Power consumption 2.5   Watts
Warranty The   GLH QC Kit is for laboratory research use by trained users. Determination of   their suitability for specific end-use is the responsibility of the user, who   assumes all liability for loss or damage arising out of the use of the   product. Warranty is limited to   replacement of defective materials, if returned with authorization, within   1-year of purchase date.